4-101
Troubleshooting
● Code : 03-014 ● Error message : Motor does not operate: #03-014. Please turn off then on.
● Symptom : Waste toner motor does not operate.
● Possible Cause:
1. Harness is defective, Connector is not connected properly.
2. Waste DC Motor is defective.
3. Engine Board is defective.
● Troubleshooting method :
‘Waste mot & LSU Clean‘
(CN39, 10pin)
1. Check the following.
-. Check if the Engine Board Harness is defective.
-. Check if the harness is connected to the ‘Waste Motor & LSU Clean’ Connector on Engine Board properly.
2. Check the following.
-. If the connection is no problem, enter the EDC mode and execute the Waste DC Motor test.
If the Motor is not operate, replace it.
Remove the Front OPC.
Remove the Front Cover.
Replace the Waste
DC Motor.
1
2
3
3. If the problem persists after replacing the Waste DC Motor, replace the Engine Board.