4-156
Troubleshooting
Code :
29-000
29-001
29-002
29-003
Error message
29-000 : Density calibration for yellow color is failed. Check its imaging unit
29-001 : Density calibration for magenta color is failed. Check its imaging unit
29-002 : Density calibration for cyan color is failed. Check its imaging unit
29-003 : Density calibration for black color is failed. Check its imaging unit
Symptom : The toner calibration value of the Imaging Unit is abnormal.
Possible Cause:
1. The sensitivity value of the toner density sensor is not in normal area.
2. The circuit related to CRUM has some problem.
Troubleshooting method :
Open and close the side cover (1~2 times)
If the problem persists, replace the imaging unit.
If the problem persists after replacing the imaging unit, check the relative harness and hardware part.
[case1] The sensitivity value of the toner density sensor is not in normal area.
[case2] The circuit related to CRUM has some problem.
Check the circuit related to CRUM in the imaging unit.
1
2
3
- Disassemble the CRUM part.
- Check if the sensor harness is defective or
connector is connected properly.
- Replace the imaging unit.
First, turn the machine off then re-install the imaging unit.
Turn the machine on. If the problem persists, check the following.
To be continued on next page…