- Fuser Error
OPEN Heat LOW Heat OVER Heat
Warm-Up Less than 60℃
at more than 20
seconds.
Less than Warm Up Ref. Temp
-20℃ & for more than 30 seconds
(LL) / 25s (except for LL) in Warm
Up end time.
Higher than 230℃(240℃) &For
continuous 30 seconds(5 sec)
Stand-Byor
Recoverable
Error State for
Over Heat only
N/A Less than Stand-By Ref. Temp
-40℃ & For more than 10 seconds.
- Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)
- Higher than 216℃ & for more
than 3 min.
Printing N/A Less than Printing Ref. Temp
-35℃ & For more than 10 seconds.
Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)
Power Save N/A N/A Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)
Low Power N/A N/A Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)
Other N/A N/A Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)