Code Displayed Name Meaning
State
Displayed
08-800 Bypass Feed Clutch Engages drive to pick up a paper from bypass. On[Off]
08-810 T1 Pick-Up Clutch Engages drive to pick up a paper from tray1. On[Off]
08-820 T2 Pick-Up Clutch Engages drive to pick up a paper from tray2. (Optional) On[Off]
08-830 T3 Pick-Up Clutch Engages drive to pick up a paper from tray3. (Optional) On[Off]
08-840 T4 Pick-Up Clutch Engages drive to pick up a paper from tray4. (Optional) On[Off]
08-850 Registration Clutch Engages drive to registartion rolls. On[Off]
08-860 Duplex Feed Clutch Engages drive to feed a paper into duplex path. On[Off]
08-870 Duplex Gate Clutch Engages drive to ready a paper into duplex path. On[Off]
08-920 T2 Feed Motor Run T2 Feed Motor On/Off On[Off]
08-930 T3 Feed Motor Run T3 Feed Motor On/Off On[Off]
08-940 T4 Feed Motor Run T4 Feed Motor On/Off On[Off]
7) Developer
Code Displayed Name Meaning
State
Displayed
09-100 MHV Bias MHV bias voltage on at normal drive level On[Off]
09-110 MHV Bias Read Detect what the MHV value is on the MHV Roller Numeric 3 digits
09-200 Dev Bias Dev bias voltage on at normal drive level On[Off]
09-300 THV(+) Bias THV plus bias voltage on at normal drive level On[Off]
09-310 THV Bias Read Detect what the THV value is on the THV Roller Numeric 3 digits
09-400 THV(-)Bias THV minus bias voltage on at normal drive level On[Off]
09-500 SMPS Fan Run Start/Stop Deve. Fan run On[Off]
09-510 SMPS Fan Run Ready Detects if Deve Fan runs at normal speed. High[Low]
09-600 Toner Dispense Motor Toner Dispense Motor On/Off On[Off]
09-700 Toner Sensor TC sensor in developer tank. Numeric 3 digits
09-800 Detach Bias Detach bias voltage on at normal drive level On[Off]
8) Fuser
Code Displayed Name Meaning
State
Displayed
10-100 Fuser Power On It controls temperature of fuser as 180 degrees. On[Off]
10-200 Fuser Temperature A Detects what the temperature A is on fuser. Numeric 3 digits
10-210 Fuser Temperature B Detects what the temperature B is on fuser. Numeric 3 digits
10-300 Fuser Unit Fault Detects if the IH board for controling fuser is normal. Normal/Fault
10-400 Fuser Motor Forward Fuser Motor Forward On/Off On[Off]
10-500 Fuser Fan Run Start/Stop Fuser Fan run On[Off]
10-600 Fuser Bias Fuser bias voltage on at normal drive level On[Off]