5. If oil level is above H mark, the drain
valve (P) on the bottom of oil pan is to be
opened to discharge extra oil. Check oil
level again.
6. Tighten the fi ller cap and properly close the
engine hood if oil level is normal.
Remark:
If you need to check oil level after operation
of the engine, shut off the engine and wait at
least for 15 minutes before checking.
If your machine is on a slope, move it to a
level ground before inspection.
For the type of engine oil used on the machine
see “Recommended Fluids” on page 5-17.
4.1.2.7 Electric wires - check
Check whether the fuse is damaged; whether
the fuse with proper capacity is used; whether
any wire connection is off; whether wire sheath
is broken.
Check for loose terminals. Fix it if any.
Moreover, pay special attention to electric
wires when checking battery, engine, start
motor and alternator. Make sure to check for
flammable materials around battery. Immedi-
ately remove them if any.
●
If any fuse burns frequently or any wire
shows the sign of short circuit, contact
your Sany distributor to fi nd the cause
and eliminate the trouble.
●
Keep battery surface clean and check
the vent on battery cover. Flush the
cover to clean the vent if the vent is
plugged by dirt or dust.