Safety, Operation and Maintenance Manual - Aug 20126-32
SY115C9/135C/155H Crawler Hydraulic Excavator
6.8.3 Jump-starting the engine
Never let the positive terminal (+) con-
tact with the negative terminal (-) when
connecting the cable.
Keep a normal machine away from
the faulty machine in order to prevent
sparks around the battery from burning
the hydrogen released from the battery.
Avoid mistakes in connection of the
jumper cable. Its nal connection with
upper structure of the machine can
produce sparks. In this case, the bat-
tery shall be connected to a location
that is far enough from the battery. (But
the work tool shall be excluded as the
work tool is not a good conductor.)
When removing the jumper cables, pay
extra attention to the cables, whose
clips shall not contact with each other
or with the chassis.
Fig. 6-23
CZ335-1103221
WARNING
Note:
The start system of the machine is sup-
plied with a 24V power source. Two 12V
batteries are connected serially to supply
power to a normally-operating machine.
The sizes of jumper cables and clips shall
match the size of battery.
Generally, the batteries of the machine
shall have the same capacity with the en-
gine to be started.
Check the cables and clips for damage or
corrosion.
Make sure that the cables and clips are
connected securely.
Check both machines whether their lock-
out controls and brake levers are in the

Table of Contents