Troubleshooting
Safety, Operation and Maintenance Manual - Aug 20126-26
SY115C9/135C/155H Crawler Hydraulic Excavator
Failure Causes Remedy
Arm slow and weak
Sensor failure
Short circuit of harness (grounding failure)
Open circuit of harness
Controller failure
Replace
Check/repair
Check/repair
Replace
Bucket slow and weak
Sensor failure
Short circuit of harness (grounding failure)
Open circuit of harness
Bucket con uence solenoid valve failure
Controller failure
Replace
Check/repair
Check/repair
Replace
Replace
Travel slow and weak
Sensor failure
Short circuit of harness (grounding failure)
Open circuit of harness
Controller failure
Replace
Check/repair
Check/repair
Replace
Monitor black-out
Fuse failure
Open circuit of wire
Short circuit of wire (grounding failure)
Monitor failure
Replace
Check/repair
Check/repair
Replace
Monitor displays nothing.
Resistor failure
Open circuit of wire
Short circuit of wire (grounding failure)
Monitor or controller failure
Replace
Check/repair
Check/repair
Replace
Dual-travel speed failure
Dual travel speed solenoid valve failure
Open circuit of wire
Short circuit of wire (grounding failure)
Replace
Check/repair
Check/repair
Engine coolant tempera-
ture reading incorrect
Coolant temperature sensor failure
Open circuit of wire
Short circuit of wire (grounding failure)
Wire short-circuited with 24V
Replace
Check/repair
Check/repair
Check/repair
Fuel level reading incor-
rect
Fuel level sensor failure
Open circuit of wire
Short circuit of wire (grounding failure)
Wire short-circuited with 24V
Replace
Check/repair
Check/repair
Check/repair
Wiper failure
Wiper motor internal failure
Open circuit of wire
Short circuit of wire (grounding failure)
Repair/replace
Check/repair
Check/repair
Arm-in pilot pressure
reading incorrect
5V power supply failure
Open circuit of signal line
Short circuit of signal line
Sensor failure
Repair/replace
Check/repair
Check/repair
Replace
Arm-out pilot pressure
reading incorrect
5V power supply failure
Open circuit of signal line
Short circuit of signal line
Sensor failure
Repair/replace
Check/repair
Check/repair
Replace

Table of Contents