-34-
Electrical Adjustments
Item No. NAME Device
XGA
Range Description
PC
Component Video
HDTV 480p 480i NTSC PAL
109 R MIN L3E7072K0A 335
110 R_MID2 L3E7072K0A 532
111 R_MID1 L3E7072K0A 645
112 R_MAX L3E7072K0A 695
113 G MIN L3E7072K0A 335
114 G_MID2 L3E7072K0A 532
115 G_MID1 L3E7072K0A 645
116 G_MAX L3E7072K0A 695
117 B MIN L3E7072K0A 335
118 B_MID2 L3E7072K0A 532
119 B_MID1 L3E7072K0A 645
120 B_MAX L3E7072K0A 695
121 G_V1 (DAC) M62398FP 100
122 R_V1 (DAC) M62398FP 100
123 B_V1 (DAC) M62398FP 100
124 REF_G (DAC) M62398FP 203
125 REF_R (DAC) M62398FP 203
126 REF_B (DAC) M62398FP 198
127 G_LCCOM (L3E06100) L3E6100 105
128 R_LCCOM (L3E06100) L3E6100 105
129 B_LCCOM (L3E06100) L3E6100 105
130 SyncPosition L3E7072K0A 0 Link with 9-131
131 SyncVideoPosition L3E7072K0A 0 Link with 9-130
132 Color Shading SW L3E7072K0A 1 Color Shading Correction, 0: Off, 1: On (Not memorized)
Group 100 OPTION (Lamp Time, Service Port etc)
1 RS232C Baudrate PW185B 0 0 : 19200bps 1: 9600bps
2 PJLink Enable MCI 1 0-1 0:Disable 1:Enable
5 PW Debug Command Enable PW185B 1 0-1 0:Disable 1:Enable(Sanyo Serial Command Disable)(Not memorized)
6 Device Refresh Disable PW185B 0 0-1 0:Enable 1:Disable(Not memorized)
20 Projector Time Reset PW185B 0 0-20 Resets Projector time when the value is set to 10.
21 Lamp Warning Time (NORMAL) PW185B 2000 0-10000 Normal lamp warning time
22 Lamp Warning Time (ECO) PW185B 3000 0-10000 Eco lamp warning time
30 Lamp life test enable PW185B 0 0-1 0:Disable 1:Enable For safety test purpose
31 Lamp On time for life test PW185B 1 1-720 For test purpose
32 Lamp Off time for life test PW185B 3 1-720 For test purpose
33 Lamp total time for life test PW185B 0 0-32767 For test purpose
40
Memory viewer please wait display
disable
PW185B 0 0-1 0: disable 1:Enable, Prohibit a part of Memory Viewer function
50 RC Mode PW185 0 0-1
Group 101 OPTION (Signal Processing)
2 Shoot Out Mode PW185B 0 1: Shoot Out Mode Enable0: Disable
3 Frame Lock SW PW185B 0 0:Not V-Sync, 1:V-Sync
5 Non Brand PW185B 0 0:Normal1:Non Brand
6 Monitor Error Count PW185B 5 Threshold value of Monitor error count
7 CABLE SW PW185B 0 Cable switch
Group 103 PW185B Image Control
PC COMPONENT VIDEO
PC HDTV 480i VIDEO SCART
0 Center Contrast PW185B 512 512 512 512 512 PW185B CONTRAST Center adjustment
1 Center Brightness PW185B 512 512 512 512 512 PW185B BRIGHTNESS Center adjustment
2 Center Color PW185B 512 475 475 475 425 PW185B COLOR Center adjustment
3 Center Tint PW185B 90 82 82 82 82 PW185B TINT Center adjustment
4 Center Sharpness PW185B 16 16 16 16 16 PW185B SHARPNESS Center adjustment
5 Alpha Contrast PW185B 40 40 40 40 40 PW185B CONTRAST Range adjustment
6 Alpha Brightness PW185B 140 140 140 140 140 PW185B BRIGHTNESS Range adjustment
7 Alpha Color PW185B 70 70 70 70 70 PW185B COLOR Range adjustment
8 Alpha Tint PW185B 10 10 10 10 10 PW185B TINT Range adjustment
9 Alpha Sharpness PW185B 10 10 10 10 10 PW185B SHARPNESS Range adjustment
Group 104 PW185B Auto PC Adjust Control
0 AutoPCAdjustEnable PW185B 0 0-1 0:Auto1:Prohibit Auto PC Adj.
1 Frequency Step PW185B 2 0-3
2 Frequency Threshold PW185B 5 0-10
3 Fine Phase PW185B 1 0-1
4 BLKDET PW185B 1 0-3 Black Level Detecte Area
5 PHASEMSK PW185B 0 0-3
Phase Detection Filter0:Effect all bits1:Disable lower 1 bit2:Disable lower 2
bits 3:Disable lower 3 bits
Group 105 Custom Mode
0 Connecting to H/V PW185B 0 0-1 Link H and V, 1: On, 0: Off
1 Vertical Scaler PW185B 100 0-200 Vertical Scaler Edit (Unit %)
2 Vertical Position PW185B 100 0-200 Vertical Position Correction (Unit %)
3 RESET/STORE PW185B 0 0-1 Reset Vertical Aspect 0:Reset, 1:Save0
4 Horizontal Scaler PW185B 100 0-200 Horizontal Scaler Edit (Unit %)
5 Horizontal Position PW185B 100 0-200 Horizontal Position Correction (Unit %)
6 RESET/STORE PW185B 0 0-1 Reset Horizontal Aspect 0:Reset, 1:Save0
7 CUSTOM ON/OFF PW185B 0 0-1 Custom function On/Off 1: On, 0:Off
Group 110 Dimmer Processing for Ballast type
0 DIMMER_CTRL_LEVEL1 PW185B 14 Luminance Level1:Dimmer Level1 when less than the value. Link with 100-7
1 DIMMER_CTRL_LEVEL2 PW185B 27 Luminance Level2:Dimmer Level2 when less than the value.