-44-
Check the indicators for projector condition.
• • • green.
• • • red • • • off
• • • blinks green.
When the life of the projection lamp draws to an end, the LAMP REPLACE indicator lights yellow. When
this indicator lights yellow, replace the projection lamp with a new one promptly. Reset the lamp replace-
ment counter after replacement of the lamp.
Indicators and Projector Condition
• • • blinks red.
Troubleshooting
Indicators
Projector Condition
POWER
red/green
WARNING
red
LAMP
REPLACE
yellow
The projector is off. (The AC power cord is unplugged.)
The projector is preparing for stand-by or the projection lamp is
being cooled down. The projector cannot be turned on until cool-
ing is completed.
The projector is ready to be turned on with the POWER ON-OFF
button.
The projector is operating normally.
The projector is in the Power management mode.
The temperature inside the projector is abnormally high. The pro-
jector cannot be turned on. When the projector is cooled down
enough and the temperature returns to normal, the POWER indi-
cator emits a red light and the projector can be turned on. (The
WARNING indicator keeps blinking.) Check and clean the air fil-
ters.
The projector has been cooled down enough and the temperature
returns to normal. When turning on the projector, the WARNING
indicator stops blinking. Check and clean the air filters.
The projector detects an abnormal condition and cannot be turned
on. Check power supply circuit and fans control circuit.