-30-
Electrical Adjustments
1. Enter the service mode.
2. Receive the 16-step grey scale composite video sig-
nal with Video[Video] mode.
3. Connect an oscilloscope to test point TP35G (+)
and chassis ground (-).
4. Select group no. “100”, item no. “6” and change data
value to adjust amplitude “a” to be 1.6 ±0.1V.
(a)
white level
white level
. 50% White adjustment [Video]
1. Enter the service mode.
2. Receive the 16-step grey scale composite video sig-
nal with Video[Video] mode.
3. Select group no. 100item no. 7(Red) or 8(Blue),
and change Data values respectively to make a prop-
er white balance.
Confirm that the same white balance is obtained in video
and computer input.
⁄0 White Balance adjustment [Video]
Note On White Uniformity Adjustment
If you find the color shading on the screen, please ad-
just the white uniformity by using the proper computer
and “Color Shading Correction” software supplied sep-
arately.
The software can be ordered as follows;
COLOR SHADING CORRECTION Ver. 4.00
Service Parts No. 645 075 9611