-39-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
2 B-LCCOM 345 0-511
3 R-LCCOM-Gain 189 0-255
4 G-LCCOM-Gain 189 0-255
5 B-LCCOM-Gain 189 0-255
6 R-LCCOM-Bright 0 0-255
7 G-LCCOM-Bright 0 0-255
8 B-LCCOM-Bright 0 0-255
9 R-LCCOM-Cent 16 0-63
10 G-LCCOM-Cent 16 0-63
11 B-LCCOM-Cent 16 0-63
12 R-ENBX-PW 11 0-127
13 G-ENBX-PW 11 0-127
14 B-ENBX-PW 11 0-127
15 R-DXIN 8 0-255 Link with No.18
16 G-DXIN 8 0-255 Link with No.19
17 B-DXIN 8 0-255 Link with No.20
18 R-CLXIN 8 0-255 Link with No.15
19 G-CLXIN 8 0-255 Link with No.16
20 B-CLXIN 8 0-255 Link with No.17
21 R-ENBX1IN 2 0-255
22 G-ENBX1IN 2 0-255
23 B-ENBX1IN 2 0-255
Group102 : Auto Keystone Setup Value
0 OFFSET 0
-1056 -
1056
1 OFFSET SWITCH
0
0 - 1
2 DEBUG MODE
0
0 - 1
3 SERVICE CALIBRATION
0
0 - 1
4 LOCK COUNT
5
1 - 255
5 DELT VERT RESULT
64
1 - 255
6 ANGLE 1 COUNT
1
1 - 10
7 ANGLE 2 COUNT
5
1 - 10
8 BLIND SECTOR 1
160
0 - 1024
9 BLIND SECTOR 3
32
0 - 1024
10 BLIND SECTOR BIAS
61
0 - 1024
Group
200
Option
0
Logo Prohibition (Forced No
Brand)
Logo Prohibition (0: Menu, 1: Forced,
2: China, 3-9: not used)
0 0 - 2 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps, 1: 9600bps, 2:
115200bps
2 PJLink Enable PJLink 0 0 - 1 0: Disable 1: Enable
3 Shipping Setting 0 0 - 20
Default set when the value is set to
10
4 CABLE SW Long Cable 0 0 - 10 0: Disable, 1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
20 Projector Time Reset 0 0 - 20
Projector Time is cleared when the
value is set to 10
21
Lamp Warning Time
(NORMAL)
Lamp Life at Normal Mode (Warning
Time at Normal)
500 -
8000
22 Lamp Warning Time (ECO)
Lamp Life at Eco Mode (Warning
Time at Eco)
500 -
8000
23 Lamp Warning Time (HIGH)
Lamp Life at High Mode (Warning
Time at High)
500 -
8000
30 Lamp life test enable
0:Disable 1:Enable, for safety test
only
31 Lmap On time(for life test) For test purpose
32 Lamp Off time(for life test) For test purpose
33 Lamp total time(for life test) For test purpose
40 PreScaler n/a 0-255 n/a
41 Htime n/a 0-65535 n/a
50 Lamp Replacement Display Lamp Warning Display On / Off 1 0 - 1 1: On, 0: Off
51 Filter Warning Display Filter Warning Display On / Off 1 0 - 1 1: On, 0: Off
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
54
Factory Default Execute
Times
Reset times of Fanctory Default 0 0 - 255 Read only