-7-
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn the projector over and remove the filters by pulling
the latches upward.
1
2
Filters prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a “Filter warning” icon appears on the screen, clean the filters
immediately. Clean the filter by following the steps below.
Gently clean the filters by using a brush or rinse them
softly.
3
When rinsing the filters, dry them well. Replace the
filters properly. Make sure that the filters are fully
inserted to the projector.
4
CAUTION
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
RECOMMENDATION
We recommend avoiding dusty/smoky environments when
you operate the projector. Usage in these environments may
cause poor image quality.
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service station for proper
cleaning.
Note:
When reinserting this filter, be sure that the slit
part is facing the outer side.
Be sure to reset the Filter counter after cleaning or replacing the filter.
Press the MENU button to display the On-Screen Menu.
Use the Point 7 8 buttons to move the red frame point-
er to the Setting Menu icon.
Use the Point ed buttons to move the red frame point-
er to Filter counter and then press the SELECT button. A
dialog box appears showing the total accumulated time
of the filter use, a timer setting option, and the reset op-
tion. Select Reset and the “Filter counter Reset?” ap-
pears. Select [Yes] to continue.
1
2
Resetting the Filter Counter
Filter counter
Another confirmation dialog box appears, select [Yes] to
reset the Filter counter.
3
Cleaning the Filter
Maintenance
Filters
Pull up and remove.
Select Reset and the “Filter
counter Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again to reset
the Filter counter.
On 1

Table of Contents

Other manuals for Sanyo PLC-XU115

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XU115 and is the answer not in the manual?

Sanyo PLC-XU115 Specifications

General IconGeneral
Projection distance0.93/11.47 m
Vertical scan range50 - 100 Hz
Horizontal scan range15 - 100 kHz
Projection technologyLCD
Contrast ratio (typical)500:1
Projector native resolutionXGA (1024x768)
Keystone correction, vertical-40 - 40 °
I/O portsSD Card Slot
Audio input1
Aspect ratio4:3
Special featuresSoft Carry Bag
Networking featuresEthernet & Wireless
F-number (relative aperture)1.7
Lamp typeNSH
Lamp power275 W
Light source typeLamp
Service life of light source2000 h
Service life of light source (economic mode)3000 h
Dot clock scanning frequency140 MHz
Analog signal format systemNTSC, PAL, SECAM
Serial interface typeRS-232
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Power consumption (typical)266 W