II - 2
Design of W-ECO MULTI SYSTEM
2
TD831077
1. Model Selecting and Capacity Calculation
1-1. Opertating range
Cooling
Heating
: Rated conditions
10
–15
–10
–5
0
5
10
15
20
15.5
25
Indoor air intake temp. °C (DB)
606_8132
Outdoor air intake temp. °C (WB)
15
27
20 25 30
Operating
range
Cooling operating range
When combined with the AD unit, outdoor air intake temp for operating range is
between 5°C and 43°C.
10
–10
–5
0
5
10
15
20
25
30
35
40
45
Indoor air intake temp. °C (WB)
1750_M_I
Outdoor air intake temp. °C (DB)
15
14
43
20 25 30
Operating
range
NOTE