3
3 - 40
Control of Mini ECO-i SYSTEM
4. System Controller
D: ON button This button is for turning the selected air conditioner on.
E: OFF button This button is for turning the selected air conditioner off.
F: Operation lamp This lamp lights when the unit is turned on.
G: MODE button Use this button to select one of the following 5 operations:
(AUTO) : Used to automatically set cooling or heating operation.
Only for heat pump type
(Temperature range: 17 to 27°C)
(HEAT) : Used for normal heating operation.
Only for heat pump type
(Temperature range: 16 to 26°C)
(DRY) : Used for dehumidifying without changing the room temperature.
(Temperature range: 18 to 30°C)
(COOL) : Used for normal cooling operation.
(Temperature range: 18 to 30°C)
(FAN) : Used to run the fan only, without heating or cooling operation.
When the indication is displayed, you cannot change the
mode from
and
or to or and . To change the mode, turn off all
units once then select the mode again.
H: Temperature setting
buttons
: Press this button to increase the temperature setting.
: Press this button to decrease the temperature setting.
I: FAN SPEED button
(AUTO) : The air conditioner automatically decides the fan speed.
(HI) : High fan speed
(MED) : Medium fan speed
(LO) : Low fan speed
J: FLAP button
1. Use this button to set the airflow direction to a specific angle.
The airflow direction is displayed on the remote control unit.
Operation mo
de Number of airflow direction settings
(COOL) or (DRY) 3
(HEAT) or (FAN) 5
(AUTO)
Cooling mode: 3
Heating mode: 5
In the Cool mode and Dry mode, when the flaps are set in a
downward position, condensation may form and drip around
the vent.
Do not move the flap with your hands.
This function is available only for models X, T and LD.
()
2. Use this button to make the airflow direction sweep up and down
automatically.
Press this button several times until the ( ) symbol appears on
the display.
This function is available only for models X, K, T and LD.
1) The flap setting can be performed only for units that have no remote
controllers.
2) In the ALL or ZONE mode, no flap setting can be performed. If
necessary, you should select the GR mode and use the FLAP bu
tton.
NOTE
CAUTION
NOTE
NOTE
NO
TE
06-405 Mini-ECOi_TD3 11/6/06 6:18 PM Page 40