33
HEATING
Model Number : STW0622H2 / 0623H2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 2.02 / 2.24 2.5 / 2.7
Power input kW 0.025 / 0.020 0.085 / 0.075 0.460 / 0.455 0.57 / 0.55
Full load conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 2.62 / 2.94 3.1 / 3.4
Power input kW 0.025 / 0.020 0.085 / 0.075 0.590 / 0.595 0.70 / 0.69
Model Number : STW0922H2 / 0923H2 / 0925H2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 2.82 / 3.14 3.3 / 3.6
Power input kW 0.025 / 0.020 0.085 / 0.075 0.630 / 0.635 0.74 / 0.73
Full load conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 3.52 / 3.84 4.0 / 4.3
Power input kW 0.025 / 0.020 0.085 / 0.075 0.800 / 0.795 0.91 / 0.89
Model Number : STW1222H2 / 1223H2 / 1225H2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 3.90 / 4.30 4.5 / 4.9
Power input kW 0.040 / 0.035 0.100 / 0.090 0.880 / 0.875 1.02 / 1.00
Full load conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 5.00 / 5.50 5.6 / 6.1
Power input kW 0.040 / 0.035 0.100 / 0.090 1.140 / 1.135 1.28 / 1.26
Model Number : STW1522H2 / 1523H2 / 1525H2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 5.40 / 6.00 6.0 / 6.6
Power input kW 0.040 / 0.035 0.100 / 0.090 1.210 / 1.215 1.35 / 1.34
Full load conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 7.10 / 7.70 7.7 / 8.3
Power input kW 0.040 / 0.035 0.100 / 0.090 1.570 / 1.555 1.71 / 1.68
Rating Conditions : Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.

Other manuals for Sanyo STW-2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo STW-2 Series and is the answer not in the manual?

Sanyo STW-2 Series Specifications

General IconGeneral
BrandSanyo
ModelSTW-2 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals