42 ACU-280 SATEL
AMD-100 (AMD-200) / AMD-101 (AMD-201) – wireless magnetic contact. Do not
configure the detector settings (the AMD-200 / AMD-201 detector does not have two
reed switches).
AMD-102 (AMD-202) – wireless magnetic contact with input for roller shutter detector:
do not configure the magnetic contact settings [first zone] (the AMD-202 detector
does not have two reed switches).
you can configure parameters of roller shutter input [second zone]:
− number of pulses after which the roller shutter input will generate alarm,
− time period during which the defined number pulses must occur for the roller
shutter input to generate alarm.
AOCD-250 (AOCD-260) – wireless outdoor dual technology curtain detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor.
AOD-200 (AOD-210) – wireless outdoor dual technology motion detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor,
sensitivity of the dusk sensor (detection threshold).
APD-100 (APD-200) – wireless passive infrared detector. You can configure sensitivity.
APD-100 (APD-200 Pet) – wireless passive infrared detector with pet immunity up to
20 kg:
you can configure sensitivity,
do not configure the pet immunity option (the APD-200 Pet detector is always
immune to the movement of pets).
APMD-150 (APMD-250) – wireless dual technology detector. You can configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor,
manner of operation in the test mode.
ARD-100 (ARD-200) – wireless reorientation detector. You can configure sensitivity.
ART-200 – wireless radiator thermostat. You can:
select the sensor that will provide data on temperature,
select the alarm system “120. Thermostat” type output, whose settings will be used
by the thermostat,
select the alarm system output that will be used to disable the capability to switch
between the thermostat operating modes remotely. Turn on the output to enable the
“Manual setting of the valve position / temperature” operating mode.
ASD-150 (ASD-250) – wireless smoke detector. You can configure:
option to indicate alarm from other ASD-250 detectors,
option to send alarm to other ASD-250 detectors.
ATD-100 (ATD-200) – wireless temperature detector. You can configure the temperature
threshold parameters for both positions occupied by the detector (which enables two
different temperature thresholds to be programmed):
threshold type: high (when the temperature rises above the defined temperature,
alarm will be generated) or low (when the temperature drops below the defined
temperature, alarm will be generated),