EasyManua.ls Logo

Satel ACU-280 - Updating the Firmware of ABAX 2 Wireless Devices; Restoring the Controller Factory Settings

Satel ACU-280
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74 ACU-280 SATEL
4. Click the button.
5. When the connection configuration window opens, select the computer COM port through
which communication with the controller RS-232 (TTL) port is to take place.
6. When the prompt is displayed asking you whether to continue the firmware update, click
“Yes”. The controller firmware will be updated.
10.1 Updating the firmware of ABAX 2 wireless devices
During the controller firmware update, programs enabling the update of the firmware of
ABAX 2 system devices are also saved to the controller memory. If devices with outdated
versions of firmware are registered in the controller, their firmware is updated by the
controller automatically. The process of verification of the firmware of registered devices is
run after each controller firmware update, as well as after adding new devices.
If attempts to automatically update the firmware of devices fail (e.g. as a result of radio signal
interference or device power trouble), the icon will be displayed in the ABAX 2 Soft
program at the device firmware version. You can then click the button (see “Devices
status” p. 21 and “Keyfob state” p. 24) to restart the update process.
At the final phase of the firmware update, the device does not perform its normal
functions for a few seconds.
If you do not want the controller to automatically update the firmware of the devices
registered in it, enable the “No automatic update of wireless devices firmware” option
in the controller.
11 Restoring the controller factory settings
1. Power off the controller.
2. If wires are connected to the controller communication bus, disconnect them.
3. Short together the terminals CKE and DTE.
4. Power on the controller. The LED indicating the status of communication with the control
panel will start blinking.
5. When the factory default settings are restored, the LED will go off for a while and then it
will go on with steady light.
6. Open the terminals CKE and DTE.
7. Power off the controller.
8. Reconnect the wires to the controller communication bus.
9. Power on the controller.
12 Battery replacement in ABAX 2 device
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the batteries.
The manufacturer is not liable for the consequences of incorrect installation of
the battery.