EasyManua.ls Logo

Satel ACU-280 - Programming Devices Using the DLOADX Program

Satel ACU-280
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SATEL ACU-280 43
temperature,
tolerance.
ATX-230 – hardwired zone expander: NC and roller shutter. You can configure parameters
of roller shutter input [second zone]:
number of pulses after which the roller shutter input will generate alarm,
time period during which the defined number of pulses must occur for the roller
shutter input to generate alarm.
AVD-100 (AVD-200) – wireless shock detector and magnetic contact:
do not configure the magnetic contact settings [first zone] (the AVD-200 detector
does not have two reed switches).
for the shock detector [second zone]:
− you can configure sensitivity (registering a shock meeting the sensitivity criterion
will generate alarm),
− do not configure the number of shocks (the AVD-200 detector does not count up
the shocks).
ASP-100 (ASP-200) – wireless outdoor siren. You can configure:
type of acoustic signaling,
maximum duration of signaling.
ASP-205 (ASP-215) – wireless indoor siren. You can configure the signaling parameters
for both positions occupied by the siren (which enables two different types of signaling
to be programmed):
maximum duration of signaling,
type of acoustic signaling,
optical signaling option.
ASW-100 (ASW-200) – 230 VAC smart plug. You can select operating mode.
ASW-210 – flush-mounted wireless two-channel 230 VAC controller. You can select the
operating mode of the controller inputs.
Filter [Filter] – the number of consecutive communication periods without connection
between the device and the controller after which loss of communication with the device
will be reported. You can enter values from 0 to 50. Entering 0 disables the check for
device presence in the system.
Temp. corr. – you can correct the temperature information sent by the device by up to
±3.5°C.
ECO – if this option is enabled, periodical communication with the device takes place every
3 minutes. Thus the battery life can be extended up to four times.
Remember that with the “ECO” option enabled for:
detectors – delay between arming / disarming and changing the detector operating
mode (active / passive) can be up to three minutes,
ASP-215 siren – delay in starting / stopping the signaling can be up to three minutes.
8.1.3.1 Programming devices using the DLOADX program
Before making any changes, click the “Read” button, and after making the changes – the
“Write” button. The data on wireless devices are not read / written when you use buttons in
the DLOADX main menu.
ARU
In the “ARU” column:
• leave the field blank, if the device is to communicate directly to the controller,