In the “Configuration” column you can configure additional settings for the ABAX 2 devices.
ACD-220
Enter a digit from the 1 to 3 range to set the sensitivity (1 – low, 2 – medium, 3 – high).
ADD-200
Dusk sensor – enter a number from the 1 to 16 range to determine sensitivity (1 – minimum;
16 – maximum).
Temperature sensor – enter in turn:
• letter H (high temperature threshold) or L (low temperature threshold),
• number from a range of -30 to +70 (with 0.5 accuracy) to define temperature,
• number from a range of 0.5 to 10 (with 0.5 accuracy) to define tolerance.
AGD-100 (AGD-200)
Enter a digit from the 1 to 3 range to set the sensitivity (1 – low, 2 – medium, 3 – high).
AMD-100 (AMD-200) / AMD-101 (AMD-201)
Do not configure.
AMD-102 (AMD-202)
Magnetic contact – do not configure.
Roller shutter input – enter 2 digits:
1st digit – number of pulses: from 1 to 8.
2nd digit – counting time: 0 (30 seconds), 1 (120 seconds), 2 (240 seconds) or 3 (unlimited
time).
AOCD-250 (AOCD-260)
Enter 2 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
AOD-200 (AOD-210)
Enter 3 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3rd digit – sensitivity of dusk sensor: from 1 to 4 (1 – minimum; 4 – maximum).
APD-100 (APD-200)
Enter a digit from the 1 to 3 range to set the sensitivity (1 – low, 2 – medium, 3 – high).
APD-100 (APD-200 Pet)
Enter 2 digits:
1st digit – sensitivity: 1 (low), 2 (medium) or 3 (high),