USER MANUAL CA-10
10
Clock controlled arming / disarming
Arming and disarming of the system can be controlled by the control panel clock. The
installer can program the exact hour and minute of arming/disarming of the system.
Arming and disarming will occur
every day
at the specified time. The control panel may
also be armed with the clock only - then disarming will be done manually by the user.
System status telephone messaging
The owner of the facility where a CA-10 control panel is installed can check if there was
an alarm in the system by using a telephone. In order to do so, he has to call the
protected facility: the control panel will answer the call and inform about the system
status. The control panel will answer telephone calls only when the system in the entire
protected facility is armed.
When answering the call the control panel sends:
one beep a second
- if there was no alarm condition since the last arming;
voice synthesizer message
- if an alarm occurred within the last hour;
sequence of five short beeps every second
- if there was an alarm, but it
occurred more than an hour ago.
The panel can answer the calls in one of two modes:
single calling mode
- the panel answers the call after a specified number of rings
(as is the case with a standard answering machine); having answered a call, the
panel does not answer any more calls for 5 minutes;
double calling mode
- to get through to the panel, the user must call it and after
hearing a specified number of the so-called callback signals (1-second continuous
tone followed by a 4-second pause - this signal corresponds to the telephone
ringing tone) hang up and call again (within 5 minutes) - the panel will answer the
second call immediately.
The installer decides if the function is to be activated and how the control panel will
answer the phone calls (number of rings, double calling, etc.)
Control panel interfacing with DTMF (MST-1) control module
The control panel can support a module which can enable the user to perform remotely,
by means of a telephone and DTMF signals, the following operations:
check the state of partitions (armed, alarm)
check the state of zones (which of them are violated)
arm / disarm
clear alarm
bypass / unbypass zones
silent arming
control the MONO switch and BI switch outputs
The control panel may be controlled from a telephone set which the control panel is
calling during voice messaging (immediately after playback of the message from the
voice synthesizer) or, after establishing connection, from any other telephone. Details
regarding the control panel operation - see the manual for MST-1 module.