SATEL VERSA 9
there is a trouble which did not exist when the arming procedure was started.
3.3 Disarming and alarm clearing
Disarming and alarm clearing are carried out in the same way, the procedures being
interconnected. If the partition is armed and an alarm is triggered in it, then disarming will
also mean alarm clearing.
In order to clear the alarm without disarming the partition, arm again the partition in the
same mode (see: “Arming” p. 7).
3.3.1 Disarming and alarm clearing without partition selection
Enter the code and then press . Disarming / alarm clearing will take place in the
partitions to which you have access.
3.3.2 Disarming and alarm clearing in selected partition
1. Indicate partition which is to be disarmed and/or where alarm is to be cleared (press one
of the keys:
- partition 1; - partition 2).
2. Press
. Backlight of the keys will start blinking, which indicates that the code must
be entered.
3. Enter the code.
4. Press or .
3.3.3 Viewing the zones which triggered alarm
Having cleared the alarm, you can check which zones triggered the alarm (this does not
apply to the TMP zone of the control panel). The information will be available until viewing the
zones or arming the system.
Enter the code, and then press in turn . Information on the zones which
triggered alarm is presented on the LEDs designated by numbers. The blinking LED means
that the zone with number corresponding to that of the LED triggered alarm.
3.4 Quick inspection of partition status
If such an option is provided by the installer, pressing and holding down the key for
about 3 seconds will display information on the partition state (whether it is armed and what
type of arming mode is set). At the same time, the LED will come on. Information on the
partition status is provided by means of LEDs 1-3 (partition 1 status) and LEDs 16-18
(partition 2 status):
none of the LEDs is ON – partition is disarmed,
LED 1 is ON – full armed mode in partition 1,
LED 2 is ON – night armed mode in partition 1,
LED 3 is ON – day armed mode in partition 1,
LED 16 is ON – full armed mode in partition 2,
LED 17 is ON – night armed mode in partition 2,
LED 18 is ON – day armed mode in partition 2.
To terminate the function of partition state presentation, press . The keypad will quit the
function automatically after 2 minutes.