Section 5: Maintenance
SATO CX400 Service Manual PN 9001110A Page: 5-5
Circuit Board Replacement, Figure 5-4
CAUTION: Before securing the printer chassis to the base, ensure
that the power switch and light leads are routed to the right of the
unit and such that they are not being pinched.
15. Manipulate housing (5) over printer chassis (9) down to rest on printer base (7).
16. Secure housing (5) to printer base (7) using two screws (6) applied from the underside.
17. Reinstall applicable front cover/attachment.
18. Connect power switch (4) to its respective two leads and insert into face of housing (5)
oriented with the “I” position up.
19. Lower and latch print assembly (2) into operational position.
20. Close cover (1), connect power supply cord, switch power on, and test cycle.
JP12
JP14
JP15
JP17
JP29
JP18
JP11
JP16
JP2-1
External Connector
Ribbon Sensor
Eye-Mark Sensor
Motor
Gap Sensor
Print Head Open Sensor
Print Head
Ground
Daughter Board
Expansion Slot
Panel Board
JP24