Cooling system
OPM 300 en-GB 60
© Scania CV AB 2020, Sweden
Antifreeze and corrosion protection
concentration table, US gallons
35% by volume of antifreeze provides sufficient
corrosion protection.
Example:
The total volume of the cooling system is
10.6 US gallons.
The measured concentration of ethylene gly-
col is 35% by volume (freezing point -6°F).
According to the table there are 3.7 US gal-
lons of ethylene glycol in the cooling system.
The required concentration of ethylene glycol
is 45 per cent by volume (freezing point -
22°F). According to the table, 4.8 US gallons
of ethylene glycol are required in the cooling
system.
Since the cooling system already contains
3.7 US gallons, fill another 1.1 US gallons of
ethylene glycol in the cooling system (4.8 -
3.7 = 1.1USgallons).
Adequate corrosion protection
Volume of ethylene glycol (%) 35 40 45 50 60 Cooling system volume
Ice slush forms (°F) -6 -11 -22 -36 -58 (US gallons)
Volume of ethylene glycol (US gal-
lons)
2.9 3.2 3.7 4 4.8 7.9
3.7 4.2 4.8 5.3 6.3 10.6
4.8 5.3 6.1 6.6 7.9 13.2
5.5 6.3 7.1 7.9 9.5 15.9
6.6 7.4 8.5 9.2 11.1 18.5
7.4 8.5 9.5 10.6 12.7 21.1
8.5 9.5 10.8 11.9 14.3 23.8
9.2 10.6 11.9 13.2 15.9 26.4
10.3 11.6 13.2 14.5 17.4 29.1
11.1 12.7 14.3 15.9 19 31.7
12.2 13.7 15.6 17.2 20.6 34.3
12.9 14.8 16.6 18.5 22.2 37
14 15.9 18 19.8 23.8 39.6
14.8 16.9 19 21.1 25.4 42.3
15.9 18 20.3 22.5 26.9 44.9
16.6 19 21.4 23.8 28.5 47.6
17.7 20.1 22.7 25.1 30.1 50.2
18.5 21.1 23.8 26.4 31.7 52.8