Renewing the commutative,
water separating prefilter
During operation, the rotary control should point
90° towards the filter being used.
Use a suitable container. The fuel collected must
be disposed of as specified in national and inter-
national laws and regulations.
1. Switch off the filter that needs renewing. The
arrow on the rotary control should point to-
wards the filter that should remain active
during renewal.
Be careful that the valve does not pass the closed
position when the engine is in operation. A
closed position can result in the engine stopping.
In marine applications, the engine stopping rep-
resents a safety hazard.
2. Clean the filter housing externally with a
cloth.
3. Remove the cover from the filter housing.