10.3.10 Position 10 - Start ramp SET2
10.3.11 Position 11 - Stop ramp SET2
10.3.12 Position 12 - Start speed SET3
10.3.13 Position 13 - Stop speed SET3
10.3.14 Position 14 - Micro speed SET3
10.3.15 Position 15 - Dump valve delay time
For individual adjustment of start ramp
Available values:
Valuesrangingfrom0-100(0=Norampdelay,1-50=x100msdelay/step)
When activating a lever/joystick the LED-display will indicate which output that is active and its
corresponding start ramp speed.
For individual adjustment of stop ramp
Available values:
Valuesrangingfrom0-100(0=Norampdelay,1-50=x100msdelay/step)
When activating a lever/joystick the LED-display will indicate which output that is active and its
corresponding stop ramp speed
For individual adjustment of start speed
Available values:
Values ranging from 1-100
When activating a lever/joystick the LED-display will indicate which output that is active and its
corresponding start speed.
For individual adjustment of stop speed
Available values:
Values ranging from 1-00
When activating a lever/joystick the LED-display will indicate which output that is active and its
corresponding stop speed.
For individual adjustment of 1st step micro speed
Available values:
Values ranging from 1-100
When activating a lever/joystick the LED-display will indicate which output that is active and its
corresponding 1st step micros speed.
For adjustment of the dump valve delay time
A lever/joystick is required to be actuated before value can be changed.
Available values:
Valuesrangingfrom0-100(0=Nodelay,1-99=x100msdelay/step,100=Alwaysactive*
*TheDVoutputwillremainactiveafterlever/joystickactuationuntilCUisreset,
Document type Document number PageRev
Service Manual S071 C
39 of 46