BA JDE BARISTA ONE_EN
V01 | 07.2016
61
www.schaerer.comProgramming
Change over grinder if the other
grinder is empty or blocked
An activated parameter changes over auto-
matically to the second grinder with an empty
message or blockage.
Switching over to the second grinder means
that this grinder remains assigned to the bev-
erage recipe until the next empty message or
blockage.
inactive / active This parameter is automa-
tically activated if the [Sa-
me] setting has been
selected for the "Coffee
mix in both bean hoppers"
parameter.
Grounds container capacity Here you can set how much coffee grounds
cake the grounds container can contain befo-
re the instruction to empty the grounds con-
tainer appears.
Press the Settings field.
The scroll wheel appears.
Set the desired value.
Confirm by pressing the checkmark.
There is no monitoring if the setting is "0" and
is set for machine with under-counter
grounds disposal or with is also required to-
gether with the base with drawer and inte-
grated grounds container.
0 – 40 Recommended setting: 36
There is no monitoring if
the setting is "0".
The optional integrated
grounds container in the
base unit should therefore
be checked occasionally.
"Cleaning" menu item
Display text Description Setting range Notes
Profi mode cleaning Start the profi cleaning automatically when
cleaning is initiated.
All preparation steps are listed. These steps
can still be acknowledged as an option. After
all steps have been carried out and the ser-
vice doors are closed again, the cleaning can
be started via the active field.
inactive/active If cleaning is cancelled
with the field, the
cleaning prompt remains.
Cleaning operations can
also be cancelled by
switching off or power fail-
ure.
A cancelled cleaning ope-
ration can be completed
by restarting the cleaning.
"Hardware configuration"
Display text Description Setting range Notes
Mains supply voltage With this parameter you specify whether the
machine is a 100 V, 120 V or 230 V (default).
This is necessary in order to configure the
heat regulation to suit the different hot water
boilers.
This setting is performed by a service techni-
cian.
230 V
(216..244)
100 V (95..105)
120 V
(114..126)
Right grinder Inactive/active Autom. hardware detecti-
on.
Left mixer Activates the left mixer when no milk system
with milk pump is active.
inactive/active The parameter is deactiva-
ted with machines with
milk pump.
Left instant ingredient motor Activates the left instant powder motor when
no milk system with milk pump is active.
inactive/active The parameter is deactiva-
ted with machines with
milk pump.
Left powder system valve Activates the left powder system valve if a
left powder system is installed.
Inactive/active
"Grinder/brewing unit" menu item