BA JDE BARISTA ONE_EN
V01 | 07.2016
65
www.schaerer.comProgramming
Change programmed beverages Different parameters of the preset beverages
can be changed under this menu item. There
are various parameters depending on the be-
verage.
Only a reduced range of settings is available
for these parameters. Access to the range of
settings is restricted to service technicians.
All letters and
numbers
Pretreatment level steps:
1: Quick-brew coffee, ma-
ximum chamber opening,
compression pressure low
2: Chamber opening medi-
um, compression pressure
medium
3: Compression pressure
low
4 (standard): Compression
pressure medium
5: Compression pressure
high
6: Pre-brewing (1 ml/1 g),
pre-brewing time 2 sec,
compression pressure
high
7: Pre-brewing (1 ml/1 g),
pre-brewing time 2 sec,
compression pressure
high, wet pressing
(*) Possible with the
"Fresh milk system with
milk pump"..
Coffee beverage only
• Grind qty grinder
• Strokes per button
• Pretreatment level
• Water volume
• Bypass water (service technician)
• Brew accelerator water sequence (ser-
vice technician)
Depends on be-
verage
With milk (powdered or fresh milk)
• Dosing time [s] hot milk
• Dosing time [s] cold milk * (service tech-
nician)
• Dosing time [s] milk foam
• Milk powder flush water volume
• Milk powder volume
• Powder foam water volume
• Powder foam flush water volume
• Powder foam powder volume
Depends on be-
verage
With powder
• Water volume [ml]
• Powder quantity [%]
• Temperature (water)
Depends on be-
verage
With cold water
Dosage time [s]
Depends on be-
verage
Settings are made using the slider or dial
controls:
► Set the slider/dial control to the desired
value.
–
Slider control
Dial control
"Beverage parameters" menu item
Adjustment options Description Setting range Notes