Operating manual VISATRON® Oil Mist Detector VN2020 / VN2020 EX
Part number 183001 Version 3.0
117
MAINTENANCE AND REPAIR
Description
Interval every six months or after every
4,000 operating hours (whichever occurs first)
No./action
Hours
4,000
8,000
12,000
16,000
See Section
Required
parts/
tools
Or months
6
12
18
24
1.
Check the supply pressure
setting at the measuring head:
Negative pressure
< 55 mmWC (5.5 mbar)
Adjust negative pressure
Negative pressure between
55 mmWC and 65 mmWC
OK
Negative pressure above
85 mmWC
Adjust negative pressure
X
X
X
X
6.5.3
U-tube
manometer
(270532)
or
Digital
manometer
(151800)
2.
Clean the light path in the
measuring head
X
X
X
X
9.1.2
Cleaning kit
(151482)
3.
Function test using smoke tube
(mist test)
X
X
X
X
9.1.4
Smoke Test
Box (151780)
4.
Replace the air filter in the
pressure regulator unit
X
X
X
X
9.1.3
Maintenance
kit VN2020
(155006)
5.
Replace inspection cover seal
X
X
X
X
9.3.3
Maintenance
kit VN2020
(155006/
155004)
6.
Replace connection box seal
X
X
9.1.5
Maintenance
kit VN2020
(155006)
7.
Clean the intake system with
compressed air
X
X
-
Compressed
air (max. 6 bar)
8.
Replacing the seal on the
mounting plate
X
X
9.3.4
Maintenance
kit VN2020
(155006)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaller Automation Visatron VN2020 and is the answer not in the manual?

Schaller Automation Visatron VN2020 Specifications

General IconGeneral
BrandSchaller Automation
ModelVisatron VN2020
CategorySecurity Sensors
LanguageEnglish

Related product manuals