Operating manual VISATRON® Oil Mist Detector VN2020 / VN2020 EX
Part number 183001 Version 3.0
MAINTENANCE AND REPAIR
WARNING
Warning risk of oil mist explosion during maintenance work
Safe operation is conditional on no explosive atmosphere escaping into the
engine room. An explosive atmosphere that escapes can cause a risk of
explosion.
Only carry out maintenance and repair work when the engine is stopped.
The power and compressed air supply must be switched off before starting
maintenance and repair work.
Also familiarise yourself with the basic safety instructions for working with the
oil mist detector.
Section 2.4 Basic safety instructions
If the oil mist detector is operated in explosion-proof areas, the relevant safety
instructions must be observed.
Section 2.4.1 Safety instructions for potentially
explosive atmospheres
The measuring track area on the sensor unit is cleaned completely as follows:
Remove the inspection cover on the measuring head
Remove and dispose of the seal between the inspection cover and the
measuring head
Clean the diode glass, left/right
Clean the sealing surface of the “inspection cover”
Position and fit the new seal on the cleaned sealing surface
Fit the inspection cover on the seal and then secure it in place
1: Inspection cover
3: Allen torque spanner, size 5
2: 4x neck collar bolts
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaller Automation Visatron VN2020 and is the answer not in the manual?

Schaller Automation Visatron VN2020 Specifications

General IconGeneral
BrandSchaller Automation
ModelVisatron VN2020
CategorySecurity Sensors
LanguageEnglish

Related product manuals