5 FUNCTIONING AND USE COD.100S12/24.D.2018
EN
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
31
WORKING TIME (timer)
It allows to select the working time of the watermaker (1-6 hours). The timer is activated if the START button
is pushed for more than 3 seconds only.
LEVEL CONTROL
It is an optional function. For activating the automatic start/stop from floating switches select the function
Level Control to ON . Then exit from menu pushing STOP.
BY-PASS
It allows to exclude the sensor (signal pressure switch) that detects the correct cycling of the ERS. The
operation with the by-pass is necessary only in case of malfunctioning of the signal pressure switch (in
example if the system gets blocks, with the message SYSTEM BLOCKED”, not as consequence of a
real hydraulic problem, but just as consequence of the malfunctioning of the probe).
The bypass is used also during special operation like the shut down procedure (washing with chemicals).
The bypass activation is automatically removed after one single production cycle. Don’t activate the by-
pass if not necessary.
AUTOMATIC START-UP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenker SMART 100 and is the answer not in the manual?

Schenker SMART 100 Specifications

General IconGeneral
BrandSchenker
ModelSMART 100
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals