Operating mode S1 (continuous operation)
The machine may be operated continuously with the
specied power.
Operating mode S2 (short-term operation)
The machine may only be operated at maximum or
peak power for a brief time.
Noise and vibration
m Warning: Noise can have serious eects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Information on noise level per EN ISO 3744:1995,
ISO 8528-10:1998
Noise data
Sound power level L
WA
96 dB
Sound pressure level L
pA
74.6 dB
Uncertainty K
wa/pA
1.5 dB
7. Unpacking
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
• If possible, keep the packaging until the expiry of the
warranty period.
• Familiarise yourself with the device by means of the
operating manual before using for the rst time.
• With accessories as well as wearing parts and spare
parts use only original parts. Spare parts can be ob-
tained from your specialist dealer.
• When ordering please provide our article number as
well as type and year of manufacture for your equip-
ment.
m WARNING!
The device and the packaging material are not
children‘s toys! Do not let children play with plas-
tic bags, lms or small parts! There is a danger of
choking or suocating!
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the “Safety infor-
mation” and the “Proper use” together with the oper-
ating manual as a whole are observed.
• Avoid accidental start-ups of the power generator.
• Use the device in the way that is recommended in
this operating manual. This is how to ensure that
your power generator provides optimum perfor-
mance.
6. Technical data
Power generator Digital inverter
Protection category IP23M
Continuous output P
n
(COP)
(230 V) (S1)
3.0 kW
Max. power P
max
(230 V) (S2 5min) 3.2 kW
Max. power P
peak
(230 V) (S2 2s) 3.5 kW
Rated voltage U
n
230 V~
Rated current I
n
2 x 13 A (230 V~)
Rated current I
n
8.0 A (12 V)
Rated current I
n
2 x 2.1 A (USB)
Frequency F
n
50 Hz
Performance class G1
Active power factor φ 1
Quality class A
Drive motor type
4-stroke 1 cylinder
air-cooled
Displacement 141 cm
3
Max. power (engine) 3.6 kW / 4.8 PS
Fuel Super E10 petrol
Tank contents 6.3 l
Engine oil type 15W40
Oil volume (approx.) 400 ml
Consumption at full load 1.78 l/h
Max. temperature. 40 °C
Max. altitude
(above mean sea level)
1000 m
Spark plug A7RTC
Technical changes reserved!