Connection to external control
Feedback
magnetization
status
ENABLE
MAG
DEMAG
Magnetic gripper EGM-X
-L1
X1
X2
Distributor
box x-way
V1 U1
ECG-W
V1
L1
F1
L2
U2
-XT7
1
2
3
4
5
6
1 2
3
1
-PE
1
-FU2
+24V
0V
A1
A2
-KM1
V2
V3
V4
U1
U3
U4
-XT8
4
5
6
7
7
8
8
2
/+24V
/GND
Terminals control area (external)
FU2 Fuse protection control circuit
COM Communication contact, shared connection
NO Normally open contact with demagnetizing system
NC Normally closed contact with demagnetizing system
ENABLE Enable contact magnetic gripper control
DEMAG Demagnetizing contact (impulse input min. 100 ms)
MAG Magnetization contact (impulse input min. 100 ms)
24V Connection 24 VDC
ECG-W 0... wiring diagram