Translation of the original manual
Assembly- and Operating Manual
PGN-plus-P
2-Finger Parallel Gripper

Table of Contents

Questions and Answers

  • J
    James LaneAug 3, 2025
    What to do if my SCHUNK PGN-plus-P 64 Controller product does not move?
    • J
      Jacqueline SanchezAug 3, 2025
      If your SCHUNK Controller product isn't moving, several factors could be at play. First, the base jaws might be jammed due to an uneven mounting surface; check the evenness of the mounting surface. Also, verify that the pressure isn't dropping below the minimum required level by checking the air supply. Ensure the compressed air lines are correctly connected and that any unused air connections are closed. The flow control valve should be open, and the proximity switch needs to be correctly set or replaced if defective. If none of these steps resolve the issue, a component part may be defective, requiring replacement or repair by SCHUNK.
  • M
    Matthew ParkerAug 8, 2025
    Why is the gripping force dropping on my SCHUNK Controller?
    • E
      ernest10Aug 8, 2025
      If the gripping force of your SCHUNK Controller is decreasing, there are a few potential causes. Start by checking for escaping compressed air by inspecting the seals and replacing them if necessary. Also, too much grease in the mechanical movement space can be a factor, so clean and lubricate the product. Low pressure can also cause this, so check the air supply. Finally, a defective component could be the reason, in which case you should replace the component or send it to SCHUNK for repair.
  • S
    steven28Aug 15, 2025
    What to do if SCHUNK PGN-plus-P 64 Controller product is not executing the complete stroke?
    • C
      Crystal SanchezAug 15, 2025
      If your SCHUNK Controller product isn't completing its full stroke, consider these possibilities: Dirt accumulation between the cover and piston may be the problem, so clean and re-lubricate. Similarly, dirt between the basic jaws and guidance could be a factor; disassemble and clean the product. Check the air supply to ensure the pressure isn't dropping below the minimum. An uneven mounting surface can also cause this issue, so check its evenness. If these steps don't resolve the problem, a component part may be defective, requiring replacement or repair by SCHUNK.
  • A
    Ashley WebbAug 21, 2025
    How to fix abrupt opening or closing of SCHUNK Controller?
    • J
      Jason BradfordAug 21, 2025
      If your SCHUNK Controller is opening or closing abruptly, it could be due to several reasons. First, ensure there's enough grease in the mechanical guiding areas by cleaning and lubricating the product. Check the compressed air lines for any blockages or damage. An uneven mounting surface can also cause this issue, so verify its flatness. Make sure a one-way flow control valve is installed and correctly adjusted. Lastly, verify that the load isn't too large by checking the permissible weight and length of the gripper fingers.
  • E
    Elizabeth LewisAug 27, 2025
    Why SCHUNK PGN-plus-P 64 Controller does not achieve the opening and closing times?
    • H
      Holly BruceAug 27, 2025
      If your SCHUNK Controller isn't achieving the expected opening and closing times, several factors could be responsible. Ensure the compressed air lines are optimally installed; if flow control couplings are present, open them to the maximum extent that the jaw movement occurs without bouncing. Check for compressed air leaks by inspecting the seals and replacing them if necessary. Excessive grease in the mechanical movement space can also impede performance, so clean and lubricate the product. Also, verify that the load isn't too large by checking the permissible weight and length of the gripper fingers. Finally, a defective component may be the cause, requiring replacement or repair by SCHUNK.

Summary

Basic Safety Notes

Intended Use, Changes, Spare Parts

Defines product purpose, prohibits misuse, and guides on structural changes and spare parts.

PPE, Safe Operation, Transport

Mandates personal protective equipment, safe handling, and transport procedures.

Malfunctions, Disposal, Fundamental Dangers

Covers handling malfunctions, disposal, and general fundamental dangers.

Protection During Handling, Commissioning, Operation

Safety measures for handling, commissioning, and operating the product.

Protection Against Dangerous Movements and Electric Shock

Addresses risks from movements, electric shock, and necessary protective measures.

Notes on Particular Risks

Highlights specific risks like falling loads, ejected objects, and sharp edges.

Technical Data

Assembly

Installing and Connecting

Step-by-step guide for mounting the gripper and connecting air lines.

Mounting the Sensor

Instructions for mounting various types of sensors onto the gripper.

Troubleshooting

Product Does Not Move

Identifies causes and corrective actions for the product not moving.

Gripping Force Dropping

Diagnoses and resolves issues related to decreasing gripping force.

Maintenance

Servicing the Gripper

Detailed steps for disassembling, maintaining, and lubricating the gripper.