7.2 Maintenance intervals
If products are used at room temperature and the ambient and
operating conditions are adhered to, these variants are mainten-
ance-free, Technical data [
}
16].
Products for special ambient conditions are excluded, e.g.higher
temperatures, dirty environment.
Interval [Mio. cycles]
for
PGN-plus-P 40 - 240
Maintenance work
10 Clean the product dry without a degreasing
agent, check for damage and wear, if neces-
sary replace seals and wearing parts,
Disassembling and maintaining the gripper
[
}
40]
10 Treat all grease areas with lubricant,
Lubricants/Lubrication points (basic lubrica-
tion) [
}
39]
For extreme ambient and application conditions, shortened main-
tenance cycles can ensure the lifespan is maintained.
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
Reduce the lubricant intervals accordingly.
7.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point Lubricant
Metallic sliding surfaces microGLEIT GP 360
All seals Renolit HLT 2
Cylinder surfaces Renolit HLT 2

Table of Contents