EasyManuals Logo

SCHUNK PGN-plus-P 64 User Manual

SCHUNK PGN-plus-P 64
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Technical data
16
05.00 | PGN-plus-P | Assembly- and Operating Manual | en | 0389753
3 Technical data
Connection data
Designation PGN-plus-P
Pressure medium Compressed air, compressed
air quality according to
ISO 8573-1:7 4 4
Nominal working pressure [bar] 6
Minimum pressure [bar]
without gripping force maintenance
with gripping force maintenance
2.5
4
Maximum pressure [bar]
without gripping force maintenance
with gripping force maintenance
8
6.5
Pressure range for air purge [bar] 0.5 – 1
Environmental and operating conditions
Designation PGN-plus-P
Ambient temperature [°C]
min.
max.
+5
+90 / VHT: +130
IP protection class * 40 / SD: 64
Noise emission [dB(A)] ≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized
solutions for special applications in dirty ambient conditions.
More technical data is included in the catalog data sheet.
Whichever is the latest version.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK PGN-plus-P 64 and is the answer not in the manual?

SCHUNK PGN-plus-P 64 Specifications

General IconGeneral
BrandSCHUNK
ModelPGN-plus-P 64
CategoryController
LanguageEnglish