Assembly
36 210.00 | PZN-plus | Assembly and Operating Manual | en | 389374
Alternativ
for sizes 40–160:
Setting the sensor in "Standard mode"
1. Turn the sensor 1 (1) into the groove (2).
OR: Slide the sensor 1 (1) into the groove (2) until the sensor 1
(1) stops at the T-nut (3).
2. Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10Ncm
3. Adjust sensor 1 (1), see sensor assembly and operating
manual.
4. Repeat steps for sensor 2.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2), }5.3.2 [/27].