EasyManua.ls Logo

SCHUNK PZN-plus 40 - Mounting the Radio System RSS-R1;T2

SCHUNK PZN-plus 40
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembly
210.00 | PZN-plus | Assembly and Operating Manual | en | 389374 47
5. Tighten screw (4) slightly.
6. Turn the screw (5) to push the position of the control cam (6).
7. Tighten screw (4) and in doing so press the control cam (6) in
the direction of the gripper finger.
8. Slide the sensor (1) to the stop into the bracket (2).
9. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
10. Adjust sensor (1), see assembly and operating manual of the
sensor.
Variant Dust-tight:
Screw in set-screw into the side cover.
5.3.16 Mounting the radio system RSS-R1/T2
The radio system RSS-R1/T2 can be used with the following
sensors:
l
Reed switch RMS 80
Assembly
1. Install the sensor, }5.3.13 [/43].
2. Adjust the sensor, see the assembly and operating manual for
the sensor.
3. Connect the radio system, see the assembly and operating
manual for the radio system.