Maintenance
210.00 | PZN-plus | Assembly and Operating Manual | en | 389374 51
7.2 Maintenance intervals
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
l
Reduce the lubricant intervals accordingly.
Interval (million
cycles):
10 (Size 40 - 160)
5 (Size 200 - 300)
0.05 (Size 380)
Maintenance
work
l
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts,
}7.4 [/53].
The seals are in the enclosed sealing
kit., }1.4.1 [/8].
l
Treat all grease areas with
lubricant, }7.3 [/52].
l
Oil or grease external steel parts.