Loading...
Mounting
02.00|ROT
A TP |en
33
Mounting
Installing and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause seri-
ous injuries.
Before starting any work on the product: Switch off the power
supply and secure against restarting.
Ensure that no residual energy remains in the system.
CAUTION
Danger of injury due to sharp edges and rough or slippery sur-
faces
Wear personal protective equipment, particularly protective
gloves.
NOTICE
Always use the correct length of mounting screws when mount-
ing the chuck and flange. Screws that are too long may protrude
from the tapping drill hole or damage the machine spindle.
1 Preparing the mount ( 6.2, Page 34)
2 Chuck assembly ( 6, Page 33)
3 Performing a functional check ( 4.2, Page 27)
6
6.1

Table of Contents