EasyManua.ls Logo

SCHUNK ROTA TP - Page 41

SCHUNK ROTA TP
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting
02.00|ROT
A TP |en
41
The radial alignment of the distributor ring is correct if the distance
between the distributor ring cover and the distributor ring equals
a (see the "Conventional Mounting of the Distributor Ring" chapter)
( 6.3.2, Page 37)
. The ring can be aligned radially with a feeler
gauge. The air gap between the chuck body and the distributor ring
at the front and rear should be uniform over the entire circumference
(approx.
1 mm). Additional measurement and alignment can be
performed by using a magnetic dial indicator stand, which is
placed on the face side of the chuck. The dial indicator is placed
radially against the distributor ring and the distributor ring is
aligned until the dial indicator no longer indicates a significant deviation
(approx. 0.2 mm).

Table of Contents

Related product manuals