EasyManua.ls Logo

SCHUNK VERO-S - Page 18

Default Icon
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting / connection / programming of the AFS3 138 PMI
18 01.00|1372106_AFS3 138 PMI_AFS3 138 MMS |en
Note:
The programming device with order no. 9988354 that is required
to program the position measuring system is available as
additional accessory and is not included in the scope of delivery of
the AFS3 138 PMI.
Via an interface, two switching outputs "S1 + S2" are provided to
the user for clamping condition monitoring.
"Open" clamping module
"Clamped" clamping module
"Clamped without clamping pins" clamping module
Connection assignment
Connection assignment
Technical data positioning system PMI
Electrical specifications
Characterization
Value / function
Range of measurement
14 mm
Output signal
2 x PNP, each 50 mA
Power supply
18-13 V (type 24 V)
Signal conditions

Table of Contents