Mounting / connection / programming of the AFS3 138 PMI
01.00|1372106_AFS3 13
19
clamping pins
pallet clamping
module; without
pallet clamping
module; with 6 bar
Programming the switching positions for the clamping slide
monitoring with the AFS3 138 PMI
Note:
At the inductive stroke measuring system, 3 switching positions for
monitoring the clamping slide position are monitored.
Note:
The teach-in process must be completed in 410 s, otherwise the
positions will not be transferred and stored in the inductive
position measuring system.