Mounting / connection / programming of the AFS3 138 PMI
01.00|1372106_AFS3 13
8 PMI_AFS3 138 MMS |en
19
Clamping slide
position
Switching output S1
Switching output S2
Open clamping
module
0
1
Closed without
clamping pins
clamping module
0
0
Closed with clamping
pallet clamping
module; without
turbo
1
0
Closed with clamping
pallet clamping
module; with 6 bar
turbo
1
0
Programming the switching positions for the clamping slide
monitoring with the AFS3 138 PMI
Note:
At the inductive stroke measuring system, 3 switching positions for
monitoring the clamping slide position are monitored.
Note:
The teach-in process must be completed in 410 s, otherwise the
positions will not be transferred and stored in the inductive
position measuring system.