Mounting / connection / programming of the AFS3 138 MMS
01.00|1372106_AFS3 138 PMI_AFS3 138 MMS |en
23
The unit is installed to a VERO-S NSE3 quick-change pallet system
according to the following assembly steps
1 Select installation side on the quick-change pallet system.
2 Unscrew grub screw M5 clamping slide.
3 Screw on adapter piece over set-screw M5 onto clamping slide,
included in the accessory kit.
4 Unscrew fastening screws of the lid onto the AFS3 138 MMS,
remove lid.
5 Remove seals and lay to one side.
6 Select cable outlet for both sensors (selectable on the side or
bottom). Insert electronic magnetic switch in one of the two
sensor slots in the housing or transversely and rotate 90°
pointing towards the LED display. Fix sensor cable in attached
cable bushings and fix them in the housing.
7 If necessary, slide the protective cover over the sensor cable.
8 Use the enclosed closed sealing plugs to seal the cable outlet
openings that are not required; seal the cable bushings and
sealing plugs. The cable bushings and sealing plugs are included
in the scope of delivery.
9 Adjust the electronic magnetic switch, sensor head approx. 12
mm over the center of the crossing over of the two sensor
slots. Clamp sensor via attachment screw to sensor head. Use
the Allen key included in the scope of delivery.
10 Screw on housing to quick-change pallet system over the two
M4 bolts, ensuring that there is no gap between the clamping
station.
11 Integrated sensors of the system into the control.
12 Conduct inductive proximity switch function test for presence
monitoring of the clamping pallet. Open clamping system →
insert clamping pallet → close clamping system → open
clamping system → lift clamping pallet.
13 Test inductive proximity switch signal output for presence
monitoring of the clamping pallet. Signal output for clamped
clamping pallets required.
14 Program electronic magnetic switch with enclosed
programming tools. In the magnetic switch, the operating
positions "opened" and "clamped with clamping pallet" must
be programmed. For programming, the quick-change pallet
system must be actively supplied with compressed air. The
programmed switching points are indicated by a flashing LED
on the sensor head. The switching points remain saved