January 2015 Page 16
Controller Information
Machine Indicator Lights
• Power
• Status
• Water
• Clean
Code Display
Main codes - automatically displayed
F . . . . . . . Freeze Cycle
F ashes . . Freeze Cycle is Pending
H . . . . . . . Harvest Cycle
H ashes . . Manual Harvest
b . . . . . . . Binis Full
C . . . . . . . Clean Cycle
L . . . . . . . Board Locked
d . . . . . . . Test Mode
O . . . . . . . Off
E . . . . . . . Self Test Failed
1 ashes . . Max Freeze - Retrying
1 . . . . . . . Max Freeze Time Shut Down
2 ashes . . Max Harvest - Retrying
2 . . . . . . . Max Harvest Time Shut Down
3 . . . . . . . Slow Water Fill
4 . . . . . . . High Discharge Temp
5 . . . . . . . Sump Temp Sensor Failure
7 . . . . . . . Discharge Temp Sensor Failure
8 ashes . . Short Freeze - Retrying
8 . . . . . . . Short Freeze - Thin ice
Setting Codes - requires push button sequence
Water Purge Settings
A, 1, 2, 3, 4, 5
De-Scale notication
- see table to the right
Change De-Scale Notication Interval -
This feature is accessible only from standby (Status
Light Off).
1. Press and hold harvest button for 3 seconds.
This starts the Time to Clean Adjustment Mode and
displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through
the 4 settings:
Prior Effective 11/6/08
3 months 1 year
4 months 0 or disabled
5 months 4 months
6 months (default) 6 months (default)
3. Push Off to conrm the selection.