EasyManua.ls Logo

Scotsman Prodigy C0322 - Control Button Use - Continued

Scotsman Prodigy C0322
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2015 Page 32
Control Button Use - continued
Change De-Scale Notication Interval
Like the others, this feature is accessible only from standby (Status Light Off).
1. Press and hold harvest button for 3 seconds.
Starts the Time to Clean Adjustment State and displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through the 4 possible settings:
Rev 5 and up (10/08 production start)
• 1 year (8760 hours)
• 0 (disabled)
• 4 months (2920 hrs)
• 6 months (4380 hours) (default)
Prior
• 6 months
• 5 months
• 4 months
• 3 months
3. Press Off or leave untouched for 60 seconds to select the displayed interval
Test Mode Sequence Table - Air or Water Cooled
Time (seconds) On Off
0 WIV - 30 seconds WP, HGV, Comp, Fan, PV
30 WP - 10 seconds WIV, HGV, Comp, Fan, PV
40 WP, PV, HGV - 10 seconds WIV, Comp, Fan
50 HGV, Comp - 5 seconds WIV, WP, Fan, PV
55 Comp - 15 seconds WIV, HGV, WP, Fan, PV
70 None - 5 seconds All
75 HGV - 10 seconds WIV, WP, Comp, Fan, PV
85 Fan - 10 seconds WIV, HGV, WP, Comp, PV
95 None All Test Complete
Test Mode - Remote
Test Time (seconds) On Off
0 WIV - 30 seconds WP, HGV, Comp, BV, PV
30 WP - 10 seconds WIV, HGV, Comp, BV, PV
40 WP, PV, HGV - 10 seconds WIV, Comp, BV
50 HGV, Comp - 5 seconds WIV, WP, BV, PV
55 Comp - 15 seconds WIV, HGV, BV, WP, PV
70 None - 5 seconds All
75 HGV - 5 seconds WIV, WP, Comp, BV, PV
80 BV - 5 seconds WIV, HGV, WP, Comp, PV
85 None All – Test Complete