SET-UP
SET-UP
Venturi
Model(s): All
1
F08A076
Secure lower portion of the venturi [1] with:
– 2 hexagon
al bolts (with scotch grip) from
predelivery kit (refer to table below).
– 2 M8 flat washers (previously removed).
Models Bolt Torque
147A / 147B / 157A /
157B / 237A / 237B /
247A / 247B / 287A /
287B / 287C / 307A /
307B
M8 x 50
with
scotch-grip
177A / 177B / 177C /
177D / 187A / 187B /
217A / 217B / 217C /
217D / 257A / 257B /
267A / 267B
M8 x 40
with
scotch-grip
21 N•m
(15 lbf•ft)
Battery P reparation and
Installation
Refer to appropriate SHOP MANUAL for proper
procedure to activate battery.
Model(s): All
Install battery in battery support in engine
compartment.
Secure RED positive cable to battery
positive post with:
– 1 hexagonal bolt,
– 1 flat washer and
– 1 nut, all from predelivery kit.
Apply dielectric grease (P/N 293 550 004)
on positive battery post.
Cover positive battery post with rubber boot.
Model(s): RXP
sbl2006-002-100_a
NOTE: On RX
P models, RED positive cable
[1] must be installed at a 45° angle while
BLACK negative cable [2] is still accepted at
a 90° angle; refer to photo.
Model(s
): All
Secure BLACK negative cable to negative
battery post with:
– 1 hexagonal bolt,
– 1 flat washer and
– 1 nut, a ll from predelivery kit.
Apply dielectric grease (P/N 293 550 004)
on negative battery post.
WARN
ING
Always connect battery cables exactly in this
specific order. Connect RED positive cable
first, then BLACK negative g round cable.
Secure battery with supplied
– bracket,
– 2 flat washers and
– 2 nuts.
Remove red plastic cap from battery vent
elbow (if so equipped).
Install battery vent tube.
WARNING
Ensure vent tube is not kinked or obstructed.
Battery vent tube must be properly installed.
Predelivery 2007-2 5 / 22