43JDL V1.0 8 2022
5. Press 1 to edit Exact Change
6. Press # to Edit
7. Use number keys to enter an amount
8. Press # to save changes
9. Press * to exit to previous menu
ALTERNATE RULE – This funcon prevents a vend from occurring, ashes the Please Use Exact Change
message and will return the established credit amount if one or more of the coin tubes are too low to give
back the correct change for the vend.
Note: This seng must be OFF if using a bill validator only. If using a bill validator only, prices must be
divisible by the denominaons accepted by the bill validator.
1. Press Service Mode Buon
2. Press 6 for Advanced Menu
3. Use number keys to enter Password (2314)
4. Press 2 for Exact Change
5. Press 2 to set Alt Rules
6. Press 2 to toggle ON/OFF (default ON)
7. Press # to save changes
8. Press * to exit to previous menu
UNCONDITIONAL ACCEPTANCE
Sets the uncondional acceptance value. All cash box coins or bills equal to or less than this set value
will be accepted, even if the changer cannot return an equal amount of change. When set to 0 (zero), all
changer tube coins are accepted. Bills are accepted once there is enough change in the changer to pay
back the bill type.
Note: The Uncondional Acceptance set value is adjustable, but the maximum value is equal to the largest
denominaon of currency or coin accepted by the changer or validator.
1. Press Service Mode Buon
2. Press 6 for Advanced Menu
3. Use number keys to enter Password (2314)
4. Press 3 for Uncondional Acceptance menu
5. Press # to edit
6. Use number keys to enter value
7. Press # to save changes
8. Press * to exit to previous menu
MAX CHANGE
This opon prevents change from being returned to the customer unl the amount of credit has been
reduced to a value less than or equal to the programmed maximum change limit.
1. Press Service Mode Buon
2. Press 6 for Advanced Menu
3. Use number keys to enter Password (2314)
4. Press 4 for Max Change menu
5. Press 1 for current Max Change seng