EasyManuals Logo

Sega Future Tone ProjectDIVA Arcade User Manual

Sega Future Tone ProjectDIVA Arcade
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
71
ERROR DISPLAY
ERROR DISPLAY
5
ERROR DISPLAY
If an error is displayed, have the site maintenance personnel or other
qualified individuals resolve it. If someone without specialized or technical
knowledgeattempts to rectify the problem, electric shock, short circuits or
fire may result. If there is no site maintenance personnel or other qualified
individuals available, turn the power off immediately, and contact the office
listed in this manual or the point-of-purchase for this product.
If problems other than those covered in this manual arise, or if no improvements
can be noted after measures given in this manual have been taken, do not take
measures indiscriminately. Cut off the power immediately and contact the ofce
listed in this manual or the point-of-purchase for this product. Indiscriminate
countermeasures could lead to unforeseeable accidents. They could also result
in permanent damages.
Static electricity from your body may damage some electronics devices on the IC
board. Before handling the IC board, touch a grounded metallic surface so that
the static electricity can be discharged.
Do not repeatedly turn the power ON/OFF in a short period of time. Doing so may
result in breakdown or parts damage.
If you receive an error number or message not listed below, stop using the
product and send the Nu in for maintenance.
This product may display error messages in response to a range of different issues, and normal play will be disabled.
Refer to the following causes and responses to deal with these issues.
If errors arise on individual cabinets, respond to the error only on the cabinet on which the error is displayed.
For example, if the response requires you to reboot, only reboot the cabinet that displays the message.
If an error cannot be xed, turn OFF the cabinet displaying the error and continue to operate the remaining cabinets.
This manual only explains errors that arise for "Project DIVA Arcade." Refer to the Nu Service Manual regarding
errors that are common to all cabinets utilizing a Nu.
Also, if "Error 8005," which is common to machines containing a Nu, occurs, press the TEST Button while holding
the START Button. The error message will be skipped and play will be possible ofine.
NOTE: Aime cards and mobile phones cannot be used while ofine. Only guest play is possible. Also, be aware that
no menu items can be set for "SETTINGS&OPTIONS."
DISPLAY ERROR 3002
Startup Mode Error
CAUSE DIP SW setting is wrong.
COUNTERMEASURES Check that multiple cabinets are not set as "SERVER."
(See "DIP SWITCH SETTING in 9-2 REPLACING THE Nu" in the CVT
Manual, "DIP SWITCH SETTING in 15-3 REPLACING THE Nu" in the
Owner's Manual.)
3
4
5
http://op.sega.jp/op_e/

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sega Future Tone ProjectDIVA Arcade and is the answer not in the manual?

Sega Future Tone ProjectDIVA Arcade Specifications

General IconGeneral
BrandSega
ModelFuture Tone ProjectDIVA Arcade
CategoryArcade Game Machines
LanguageEnglish

Related product manuals