Paragraph 8 – Timed Dosage (Frequency signal input “TRIGGER” not activated)
Programming
Operation
PROG
Cong.
+
Cong.
Funct.
Funct.
Timer
Q.ty
100 ml
Delay
00.00.00
Interval
00.00.00
Trig.Mode
Disabled
PausMode
Restart
PausMode
Restart
PausMode
Pasue
PausMode
Freeze
The pump doses a programmed quantity in mL. It is possible to set a
delay time (Delay) for the pump start up and an interval between
subsequent dosages (Interval) as shown on the diagram:
The Delay and Interv. times are in dd.hh.mm format
(days.hours.minutes)
The Pause input can be programmed in three different modes:
1. Freeze Time: with the pause activated, the system stops the
current time count and restarts the count when the pause is
deactivated
2. Pause Dosing: with the pause activated, the system
continues to count the time and stops the dosage.
3. Restart Timer: with the pause activated, the system stops the
dosage and when the pause is deactivated the count restarts
from the beginning.
The dosage frequency can be modified during the pump operation by
pressing
+ simultaneously.
Display during operation
Function mode
Timer
Alarms and statuses
Lev = Level Alarm
Flw = Flow Alarm
Set dosing quantity
(display during the
dosing)
Pump status
empty = pump in stating
Stop = pump in stop
Paus = pump in pause
Tempo
100ml
Delay
Interv.
Quantity