* the Min, Max limit values represent the maximum values permitted and vary according to the synergic program selected.
** parameters displayed in the quick menu if enabled by the related function.
*** the maximum current value in synergy depends on the power source unit with a higher tolerance range (roughly: PSR503=500A,
PSR352=350A).
# synergic parameter correction.
MIG SHORT MANUAL
* Types of gas that can be set: 0=gas not defined (measurement performed on mean value of settable gases)
1=Ar 20%CO2
2=CO2
8=Ar 2%CO2
9=Ar 2%O2
12=Ar
13=Ar 50%HE
17=He
** parameters displayed in the quick menu if enabled by the related function.
MAIN MENU
Wire speed
Voltage
SET-UP MENU CH1 RC07
SET-UP MENU CH2 RC07
QUICK MENU
Program number
Wire speed
Voltage
Minimum current
Inductance
Spot welding time **
Pause time **
SET-UP MENU
2-Program number
3-Wire speed
4-Voltage
5-Minimum current
6-Inductance
7-Burn back
8-Softstart
9-Pre-gas time
10-Post-gas time
11- Gas type for flow
measurement
12-Spot welding time
13-Pause time
40-Current reading
41-Voltage reading
42-Gas flow reading
48-Buzzer tone
49-LCD contrast
45-CH1: min wire speed
RC07
45-CH1: max wire speed
RC07
46-CH2: min voltage
RC07
46-CH2: max voltage
RC07
27
SYMBOL MIN
Off (0)
1,0
5,0
12
12
0,01
10
0,0
0,0
0
0,1
0,1
-
-
-
Off (0)
0
1,0
min+1
5,0
min+ 0,1
MAX
60
22,0
55,5
250
100
1,00
100
10,0
10,0
17
25,0
25,0
-
-
-
10
50
max-1
22,0
max-0,1
55,5
DEF
-
-
-
0
45
0,08
50
0,0
2,0
0
1,0
1,0
-
-
-
5
25
1,0
22,0
5,0
55,5
UM
-
mt/min
V
A
%
s
%
s
s
*
s
s
A
V
lt/min
-
-
mt/min
mt/min
V
V